Solar and renewable site monitoring for inverter output, export and grid power quality
Rooftop arrays, carports and ground-mount solar are sold on expected production. Without measured AC output at the inverters and the point of interconnection, an inverter that trips on high voltage, a breaker left open or a slow decline in output can go unnoticed for months. TRACEKORE meters AC production, site load and power quality together, so owners see production against consumption and export, and the grid conditions behind every drop.
Problems we help solve
Inverters tripping on grid voltage
Inverters must disconnect when voltage or frequency leaves the limits set by their interconnection settings. On weaker services, voltage can rise at midday as export peaks and push inverters offline again and again. Measuring voltage and AC output together shows whether production drops line up with high voltage.
Underperformance nobody notices
A failed inverter, a tripped AC breaker, soiling or new shading shows up as lower output, but a monthly total hides it. Where each inverter's output is metered, comparing it with its neighbors and its own history flags a unit that falls behind.
Self-consumption versus export
The value of solar depends on how much is used on site and how much is exported under your rate. Metering site load and the interconnection point together shows self-consumption, export and the imports that still set demand charges.
Demand charges solar does not remove
Output falls with passing clouds and late in the day while the building load stays high, so one interval can still set the monthly peak. Monitoring shows the net demand the utility actually bills.
What we monitor
String and central inverters, AC combiner panels, Point of interconnection, Site main switchboard, Production meters, Rooftop, carport and ground-mount arrays, Step-up transformers, Trackers and auxiliary loads, Battery storage, where paired, EV charging fed by the site.
Example alerts
- Inverter 3 AC output 40% below neighboring inverters: check inverter and AC breaker
- Inverter offline during daylight hours: no AC output since 11:52
- Voltage at the point of interconnection above 1.05 pu: inverter trip risk
- Net demand spike at 4:30 PM as solar output fell: new monthly peak
- Export exceeded site load for 4 hours: self-consumption opportunity
- Current harmonic distortion rising at inverter output
Where the energy goes to waste
Typical patterns we find in this kind of facility.
Production lost to repeated inverter trips
Each trip takes an inverter offline for minutes while it waits to reconnect. On sunny days with high service voltage, repeated trips can add up to a meaningful share of production that nobody sees in the monthly total.
Production lossOutages that go unnoticed for weeks
An inverter fault or an open AC breaker after maintenance can leave part of an array producing nothing. Daylight hours with no output on a metered inverter are flagged the same day.
AvailabilityExporting energy that could offset purchases
Where export is credited at less than the retail rate, shifting flexible loads such as charging, pre-cooling or pumping into solar hours could keep more of the production on site.
Self-consumptionPower quality
Inverter-based generation changes power quality at a site. Inverters inject harmonic current, raise local voltage when exporting and respond to grid disturbances by riding through or tripping. Measuring both production and the service shows which is happening.
Voltage rise at the point of interconnection
Exporting through a long or weak service raises voltage at the site. It can push inverters toward their trip settings and stress other equipment on the same service. Phase voltages measured against production show how close the site runs to those limits.
Inverter harmonics and resonance
Inverters produce harmonic current, and the interaction with power-factor correction capacitors can create resonance. Where the installed meters support it, harmonic distortion is tracked at the inverter output and the service.
Ride-through and trip events
Voltage sags and frequency events make inverters ride through or trip. Time-stamped events next to the production trace show which grid events took production offline and for how long.
Numbers worth tracking
| Metric | What it shows | Why it matters |
|---|---|---|
| Measured AC production | kWh by inverter and site | Compare with expected production and with similar inverters |
| Self-consumption ratio | % of solar used on site | Higher on-site use could mean more bill value, depending on your rate |
| Inverter availability | % of daylight hours producing | Exposes trips and outages hidden in monthly totals |
| Net peak demand | kW billed after solar | Shows whether solar is actually reducing demand charges |
What is measured depends on the meters installed at your site; the portal shows only values your meters can measure. Percentages and benchmarks on this page are general estimates from industry and market research. They could differ at your facility and are not guarantees.
Solar & Renewable Energy Sites energy monitoring: common questions
Plain answers to the questions people search for most. Grounding and power-quality notes are guidance for a qualified electrician, not a diagnosis.
Why does my solar inverter keep tripping offline?
Common causes are service voltage rising above the inverter's trip settings while the site exports at midday, frequency events on the grid, AC-side breaker or wiring problems, and inverter overheating. Measuring voltage at the inverter or interconnection next to its output shows whether trips line up with high voltage. Your installer or electrician confirms the cause; persistent high service voltage may need the utility to review.
How do I know if my solar system is underperforming?
Compare measured AC output with what the system should produce for the conditions, and compare similar inverters with each other. A sudden drop on one inverter usually means a fault or an open breaker; a slow decline across the array points to soiling, shading or degradation.
Does solar reduce my demand charges?
Only if it is producing during the interval that sets the monthly peak. Passing clouds and late-afternoon peaks mean solar alone often leaves demand charges in place. Net demand data shows what the utility actually bills after solar.