TRACEKORE
Industries / Commercial Real Estate

Commercial real estate energy monitoring for common areas, tenants and central plant

Commercial property owners face energy costs from two directions: common area expenses that come directly off NOI, and tenant-consumed energy that drives lease negotiation, disputes, and satisfaction. TRACEKORE gives landlords and property managers circuit-level visibility into both — separating common area from tenant consumption, identifying waste in systems you control, and providing documentation when energy costs are passed through.

Problems we help solve

  • Common area energy with no occupancy relationship

    Lobby lighting, elevator systems, parking garages, and common corridor HVAC run on schedules that often do not reflect actual building occupancy. Monitoring these systems separately from tenant loads shows exactly what you are spending on spaces you control.

  • Tenant energy use that cannot be verified

    In properties with master metering or where submetering has not been fully implemented, tenant energy consumption must be estimated for allocation. TRACEKORE supports tenant-level submeter monitoring that documents actual consumption for lease reconciliation.

  • HVAC systems serving both common and tenant areas

    Shared HVAC plants that condition both common areas and tenant floors make it difficult to accurately allocate energy cost. Monitoring at the air handler level provides consumption data that supports more accurate allocation.

  • After-hours tenant requests and overtime HVAC

    Tenants requesting after-hours HVAC generate consumption that is often undercharged or unapparent. Monitoring HVAC circuit consumption tied to after-hours requests shows actual cost and supports accurate recovery.

What we monitor

Elevator and escalator systems, Lobby and common area HVAC, Parking garage lighting, Exterior building lighting, Rooftop HVAC serving tenant floors, Chiller and boiler plants, Common area lighting, Tenant submeter circuits, Building security systems, Irrigation and landscaping.

Example alerts

  • Parking garage lighting on during daylight hours: photocell issue
  • Common area HVAC running at full capacity: building unoccupied
  • Elevator motor current anomaly: bearing inspection recommended
  • Lobby lighting on past midnight: timer or control failure
  • Tenant floor 6 HVAC drawing 35% above normal: after-hours event
  • Chiller plant energy 22% above last week: check cooling tower

Where the energy goes to waste

Typical patterns we find in this kind of facility.

Common area lighting on fixed schedules

Parking garage, lobby, and exterior lighting on fixed timers rather than photocell or occupancy control often results in hours of unnecessary illumination daily. Monitoring shows runtime against daylight hours and occupancy patterns.

Scheduling waste

HVAC in unoccupied tenant spaces

Vacant tenant spaces that remain connected to the HVAC plant and receive conditioning add to your energy bill with no lease revenue to offset it. Monitoring vacant space consumption separately allows you to quantify and control this cost.

Vacancy energy

Chiller and boiler plant inefficiency at partial load

Central HVAC plants are designed for peak load but spend most of the year at partial load. Chiller and boiler energy monitoring shows actual plant efficiency across operating conditions and identifies when staging strategies should be adjusted.

Plant efficiency

Power quality

Commercial office buildings present power quality challenges driven by the concentration of IT equipment, UPS systems, and variable-speed drives in elevators and HVAC. In older buildings, the addition of significant electronic loads to infrastructure not designed for them creates harmonic and power factor concerns.

Elevator drive harmonics in older buildings

Variable-frequency drives on elevator systems generate harmonic currents that can affect other building systems sharing the same electrical infrastructure. This is particularly common in buildings that have modernized elevators but not electrical distribution.

Harmonic loading from tenant IT infrastructure

Office tenants with significant server rooms, UPS systems, and electronic workstation loads introduce harmonic currents that can heat building electrical infrastructure. TRACEKORE monitors current anomalies that indicate harmonic loading.

Power factor and utility surcharges

Large commercial buildings with significant inductive loads — HVAC motors, elevator drives, and older lighting — can attract utility power factor surcharges. Monitoring power factor by panel allows you to identify which systems are contributing most.

Numbers worth tracking

MetricWhat it showsWhy it matters
Common area kWh per sq ftCommon area intensityBenchmark against property class and climate zone
Vacancy energy cost$/month unoccupiedDirect cost of conditioning unleased space
After-hours HVAC recovery rate% of actual costAre overtime charges covering actual consumption?
Elevator energy per tripkWh per cycleTrack against baseline to detect drive or motor degradation

What is measured depends on the meters installed at your site; the portal shows only values your meters can measure. Percentages and benchmarks on this page are general estimates from industry and market research. They could differ at your facility and are not guarantees.

Commercial Real Estate energy monitoring: common questions

Plain answers to the questions people search for most. Grounding and power-quality notes are guidance for a qualified electrician, not a diagnosis.

How do I allocate energy costs to tenants accurately?

Submeter tenant circuits and shared systems, then allocate from measured consumption instead of floor area. That gives both sides numbers they can check during lease reconciliation.

Why is common-area energy so high in my building?

Lobby, corridor, garage and exterior lighting on fixed schedules, common-area HVAC running when the building is empty, and central plant equipment at inefficient part load are the usual causes. Monitoring them separately from tenant loads shows what you control.

How can I bill tenants fairly for after-hours HVAC?

Measure the HVAC circuits that serve the tenant during their after-hours requests. Actual consumption shows whether overtime charges cover the real cost.

See this for your facility

We review your electrical service, recommend the right metering, and show you what you would see on day one.